Showing results: 271 - 285 of 674 items found.
-
TA-3400 -
Tech-Aid Products
This transponder test fixture is specific to the requirements for testing Becker Avionics Transponders and provides interface connectors for both the panel mount and remote systems. The panel also provides switches to implement Gillham code altitude as well as separate interfaces for an external parallel or serial encoder. The panel will interface with the RMU 5000 or standard control head. This fixture also comes with voltage and current meters along with an internal dimming source. This panel comes in the standard 19 inch rack width and measures 12 inches in depth.
-
Interpower Corp.
The Interpower® International Power Source (IPS) provides a low-cost, convenient source of AC power at various operating voltages and frequencies found around the world (typically 110-240VAC/50-60Hz) which is important for testing any products that are exported. Output power is delivered through one of two ranges: Low range (10-138VAC) through a standard NEMA 5-20 socket and High range (10-276VAC) through any of the six standard international sockets so that products can be conveniently powered during development or just prior to shipment.
-
Maynuo Electronic Co.,Ltd
*Low ripple and low noise*High resolution and accuracy (0.1mV/0.01mA)*Built-in high-accuracy 5 1/2 voltmeter and milliohmmeter*Supporting high-accuracy and dynamic programming output*High-luminance VFD screen with two lines& four channels display*Intellegent fan system fan will be automatically initiated according to the temperature*Supporting remote voltage compensation and multidata storage*Supporting external trigger input and output*Power-on-self-test, software calibration and standard rack mount*Using standard SCPI protocol*Communication mode: RS232/RS485/USB.
-
PEWM-3C-1 -
EMSYST Ltd
The single-phase energy standard PEWM-3C-1-1 is used for a quick check on site of all types single-phase electricity meters – for active, reactive or apparent energy, electromechanical and electronic. The voltage and the current are measured at the same time. The current can be measured directly within 10A or 100A range or with current clamp to 100A. The current clamp is electronically compensated.
-
Teledyne RF & Microwave
This Low Noise Triple Band Voltage Controlled Oscillator was designed to meet a specific customer requirement. The VCO cover the 3300 to 4700 MHz frequency range in three bands. The output power is +9 to +12 dBm with an integrated buffer amplifier to minimize load pulling. The three bands are selected using standard TTL control.
-
QS30A -
Shanghai Launch Electric Co., Ltd.
QS30A high-voltage bridge takes use of combined line of current-comparator and Schering bridge. It is featured by reliable and easy operation, high precision, good linearity, automatic process of data, direct display on the panel capacitance, dielectric loss tgδ, test voltage and current flowing through the standard capacitor (Icn). It is widely used and reliable.
-
NIM Compact 150W -
W-IE-NE-R, Plein & Baus GmbH
The WIENER NIM compact series is the low-cost entry into the NIM world. This is achieved by combining the economic steel-aluminum UEN 04 bin with a very compact 150W slot power supply. The result is a lightweight NIM crate with reduced depth. To be compatible to all NIM modules the UEP15 provides all standard (6) DC voltages as well as 115V AC.
-
CoolX1800 Series -
Advanced Energy
Access incredible power via a compact supply. The modular Excelsys CoolX®1800 offers 1800 W in a 267 x 127 x 41 mm package (approximately 50% more power than the industry standard). Outputs can be parallel connected for higher currents and series connected for higher voltages (up to 348 VDC).
-
PXIS-2719A -
ADLINK Technology Inc.
The ADLINK PXIS-2719A is a 3U PXI chassis with a series of advanced features:*An innovative cooling mechanism to deliver efficient and uniform heat dissipation*Superior stability within an extended temperature range*Intelligent chassis management that dynamically monitors and manages fan speed, system voltages, and internal temperature*Remote management via standard RS-232 monitoring port
-
PCIBPC104pET -
Dynamic Engineering
PCIBPC104pET adapter / carrier converter card provides the ability to install 1-4 active PC104p or PCI-104 cards into a standard PCI slot. PCIBPC104pET has a PC104p and PCI-104 compatible stack position mounted to a universal voltage shorter than 1/2 length PCI card. The PC104p position is stackable with all 4 active positions usable.
-
ERM2 -
Bacharach, Inc.
The Parasense ERM2 is a multi-circuit utility monitor, with standard configurations of 6 or 12 three phase circuits and 24 or 36 single phase circuits. SARTs are provided to cover measurement of an extensive range from 2 to 2500 Amps. Four voltage ranges are catered for that cover most commercial, industrial and military applications, with special applications catered for on request.
-
Dove Lighting Systems, Inc.
The MTX-DE48 decodes signals from DMX control desks to analog dimmers. It is used to integrate DMX controllers into existing analog installations. The standard 0 to 10V output is compatable with many LED drivers. Output may be adjusted up to 28V for use with some older dimmer systems. A negative output voltage option is also available.
-
IRIS Instruments
The Syscal Junior is an all-purpose resistivity and induced polarization sounding and profiling system for environmental applications. The system is supplied as a standard sounding system capable of recording two measurements simultaneously, perfect for performing offset Wenner sounding arrays. The output current is automatically adjusted (automatic ranging) to optimize the input voltage values and to ensure the best measurement quality.
-
LXinstruments GmbH
Source Measure Units are high-precision multifunctional devices that combine voltage/power supply and various measurement functions in one unit. This combination eliminates the need to interconnect several units, which can otherwise be very time-consuming.In addition to the standard measurement tasks for voltage and current, devices with LCR extension can also be used to determine inductance, capacitance and resistance of the respective specimen.
-
Junction Measurement and Analysis -
Materials Development Corporation
A comprehensive set of analyses for junction diode or Schottky barriers begins with C-V data gathering that adjusts the voltage step to the slope of the C-V characteristics. This assures an optimum set of C-Vdata whether the voltage range is small or large. Doping profile and resistivity profile are both available at the touch of a key. Plots of 1/C2 - V or Log(C) - Log (V+ phi) show doping uniformity and doping slope factor. Exclusive recalculation options allow adjustment of stray capacitance and area to facilitate calibration using a standard reference wafer of known doping or resistivity.